Solis Local Hybrid Inverter
The app is built around one wired RS485 link to your inverter's COM port — reading PV, battery, grid and load in real time, and optionally driving charge, discharge, work mode and grid export.
The app connects through a small wired RS485-to-Ethernet gateway on the inverter's COM port, so Homey is the sole Modbus master: a fully local, cloud-free link with no time limit on control. The RS485 gateway section above shows how to wire it in. Only one Modbus master can talk to the inverter at a time, so don't run a second controller against it in parallel.
Local, no cloud
A wired RS485 link to the inverter, reaching Homey over your own LAN. No account, no internet dependency.
Energy dashboard
Separate Inverter, Battery and Grid devices feed Homey's Energy tab with the right roles.
Real-time control
Grid-charge, discharge, work mode and reserve SOC — field-proven local dispatch that holds indefinitely.
Solar curtailment
A Limit solar output switch you can drive from any Flow — throttle production so the inverter stops pushing power out (e.g. when prices go negative).
Grid limiting insight
See when the grid is throttling production (overvoltage / volt-watt) instead of guessing.
Follow-the-sun
Triggers that recommend an EV charging current to soak up surplus solar.
Devices
Pair the inverter first; the Battery and Grid devices then attach to it and mirror its readings without opening a second connection.
Flow cards
Triggers
| Solar surplus rises above [power] W | Power being exported to the grid crosses your threshold — divert it to a load. |
| Follow-the-sun: charge at recommended current | Emits the EV current to apply to soak up surplus solar. |
| Follow-the-sun: stop charging | Surplus no longer covers the minimum charging current. |
| Production becomes limited | The inverter starts holding back output; a Reason token says why. |
| Production no longer limited | Output is unrestricted again. |
| Grid meter feed lost | |
| Grid meter feed restored | |
| EV charge request fulfilled |
Conditions
| Production is / is not limited | |
| Solar output is / is not limited | |
| Battery charge is / is not below [soc] % | |
| Solar production is / is not above [power] W | |
| An EV charge request is / is not active |
Actions
| Set work mode to [mode] | Self-use, time of use, backup reserve or off-grid. |
| Grid charging on / off | |
| Force charge battery | Grid-charge at a current up to a target SOC. |
| Force discharge battery | |
| Cover the house from the battery, up to [max] W | Closed-loop discharge: supplies exactly what the house is drawing and holds the grid at your target, instead of a fixed power that exports the surplus. Needs a live whole-home reading. |
| Keep the grid at zero with the battery, charging up to [max_charge] W and discharging up to [max_discharge] W | Load following in both directions: an export charges the battery, an import discharges it. |
| Cover the house from the battery, leaving out the EV, up to [max] W | Like Cover the house from the battery, but your car charges from the grid: the power sent with Report EV charge power is taken off the meter reading, so the battery covers only the rest of the house. Feed that card from your charger's or EV meter's power Flow. Needs a live whole-home reading too. |
| Stop forced charge or discharge | |
| Battery discharge blocked / allowed | Block discharge to hold the battery's charge during cheap hours; allow it during expensive hours. Solar can still charge the battery while blocked. |
| Charge trim on / off | |
| Set battery reserve to [soc] % | |
| Limit grid export to [power] W | 0 W = no feed-in. |
| Remove grid export limit | |
| Limit solar output on / off | Throttles the inverter output down — the same switch as the tile. Gate it on a whole-home meter so it only curtails when you are actually exporting. |
| Switch inverter on / off | A soft switch — not an electrical isolation. |
| Report grid power [power] W | Feed a whole-home meter reading (+ import / − export) to the optimizer and self-consumption trim — the inverter can't see house load. |
| Report house load [power] W | Feed your true house consumption (excluding the EV) so the optimizer plans against real load instead of an estimate. |
| Report external solar production [power] W | For panels on a different inverter. Without it the app sees no solar at all and home consumption comes out far too low, or zero. |
| Report EV charge power [power] W | Feed your charger's power in so the battery can be planned around a live charging session instead of mistaking the car for house load. Cover the house from the battery, leaving out the EV uses it too. |
| Charge EV to [soc] % within [hours] h | |
| Cancel EV charge request | |
| Fill battery then charge EV to [soc] % | |
| Stop cheap-day fill |
Recipes
Four ready-to-build patterns. All assume no other controller is talking to the inverter over Modbus at the same time.
Stop feeding in when prices are negative
An absorb-then-curtail strategy: while the price is below zero, grid-charge the battery (you get paid to import and store it); once it's full, stop exporting.
- Absorb — when the price drops below 0, run “Force charge battery” up to 100 %. Net-importing means no feed-in, and you store cheap energy.
- Curtail — when the battery hits 100 % and you're still exporting, run “Limit solar output on”.
- Resume — when the price rises back to 0 or above, run “Stop forced charge or discharge” and “Limit solar output off”.
The curtail step throttles the inverter's output (proven on hardware — solar curtailed, export stopped). The inverter can't see your whole-home use, so gate it on your P1 meter and only curtail while the house is genuinely exporting — otherwise it would cut production you're actually using.
Save the battery for expensive hours
Hold the battery's charge while power is cheap or mid-priced, and only let it cover the house when prices peak — driven by your own price source (Tibber, Frank, EPEX, etc.). No optimizer needed.
- Hold — when the price is cheap or medium, run “Battery discharge → blocked”. The grid covers the house at the low price and the battery keeps its charge; solar still tops it up.
- Release — when the price becomes expensive, run “Battery discharge → allowed”. Self-use drains the battery to cover the house — no export, no grid import until the pack is empty.
Any Homey price app that can tell “cheap” from “expensive” drives the two Flows — no optimizer or extra hardware. While blocked, PV can still raise the SOC; it just never falls.
True home consumption from a P1 meter
The inverter can't see house loads on other circuits. Combine your P1 grid meter (HomeWizard P1, Tibber Pulse, Plugwise Smile P1, Youless, or any smart-meter reader with a Homey device) with the inverter's AC power to derive real consumption: home = grid + inverter AC. The inverter AC value is positive when delivering, negative when grid-charging.
- Create a virtual device with a measure_power capability, called “Home consumption”.
- Keep it updated with a small HomeyScript, triggered whenever the P1 power or the inverter's AC power changes:
const devices = Object.values(await Homey.devices.getDevices());
const grid = devices.find(d => d.name === 'Tibber Pulse'); // your P1 meter — e.g. HomeWizard P1, Plugwise Smile P1, Youless (use its exact name)
const sol = devices.find(d => d.name.startsWith('Solis')); // the inverter
const home = devices.find(d => d.name === 'Home consumption'); // virtual device
const g = grid.capabilitiesObj['measure_power'].value; // + = import
const i = sol.capabilitiesObj['measure_power.inverter'].value; // + = deliver / - = draw
let w = Math.max(0, Math.round(g + i)); // use i - g if your P1 imports negative
await home.setCapabilityValue('measure_power', w);
Check your P1's sign once while clearly importing: if its power reads positive, use g + i; if it reads negative, use i − g. That virtual device can then serve as your consumption source in Homey Energy.
Totals for import and export
Nothing to build — the Solis Grid device already keeps two running totals in kWh, and they survive restarts. They are deliberately kept apart, because a kilowatt-hour you buy and one you sell are rarely worth the same; subtract them yourself if you want the net figure.
- Imported energy — everything drawn from the grid since you added the device.
- Exported energy — everything fed back over the same period.
- Open the Solis Grid device and tap Insights for either figure charted per day, week, month or year; the device also feeds Homey's Energy tab as the grid meter, so a price app can put amounts against it.
Treat these as good estimates, not as a bill. The app builds them up itself by sampling power every few seconds from the moment the device was added, so they start at zero and drift slightly from your meter over months — your supplier settles on the P1 meter, not on this. What counts as "grid" also depends on your wiring: with a CT or meter fitted to the inverter it is your whole home; without one it is only the inverter's own grid port, which misses loads on other circuits.
Wire in the RS485 gateway
The app connects to your inverter over a small wired RS485-to-Ethernet gateway on the inverter's data-logger (COM) port. It's a one-time hardware install that makes Homey the sole Modbus master — fully local, no cloud, and no time limit on control.
What you need
- An RS485-to-Ethernet gateway with a Modbus TCP-to-RTU gateway mode — e.g. the Waveshare RS485 TO ETH (C). A plain transparent serial bridge will not work: it must translate Modbus TCP to RTU.
- A 12 V power supply (or PoE) for the gateway — it does not run off the inverter's COM pin.
- A connector for the inverter's COM port. The Solis data-logger port is USB-A shaped, so a USB-A male plug can be sacrificed and wired to the gateway.
- A multimeter, to confirm the pinout.
Where to buy the gateway
The Waveshare RS485 TO ETH (C) is widely stocked. These are neutral starting points — availability and price vary by region, so compare before you order.
- Waveshare — official product page and wiki
- Amazon — search the current listings
- AliExpress — often the cheapest, longer shipping
- Newegg — another reseller option
Make sure it's a model with a Modbus TCP-to-RTU gateway mode (the RS485 TO ETH (B) or (C)) — a plain transparent serial bridge will not work.
What the gateway looks like
Waveshare sells several variants and they all work as long as they have the Modbus TCP-to-RTU gateway mode. You only need a single RS485 port, so the basic model is plenty — the PoE and 4-channel versions serve more ports than one inverter needs.
PoE can save a separate 12 V adapter, but it isn't required. The 4-channel model gives you three RS485 ports more than a single inverter needs — fine if you already own one, otherwise the single-port model is the simpler pick.
Wiring & setup
- Remove the stock Solis WiFi/LAN stick from the data-logger (COM) port. This round, USB-A-shaped port is the only one that answers control commands — not the bolted meter/BMS terminals next to it.
- Identify the pins. The port uses the standard USB-A electrical layout: the two OUTER pins are power and ground, the two INNER pins are the RS485 A/B signals. A multimeter reads about 5 V between the outer pins (one GND, one +5 V).
- Wire the gateway: outer GND to the gateway's GND, and the two inner pins to the gateway's A and B. Leave the +5 V outer pin unconnected and power the gateway from its own 12 V supply. If it doesn't reply after setup, swap A and B — they're a coin-flip.
- Configure the gateway in its web UI: a static IP (e.g. x.x.x.x), Work Mode = TCP Server, Protocol = Modbus TCP to RTU, Port = 502, serial 9600 / 8N1. Reserve that IP in your router.
- In the Solis Inverter device settings in Homey, set the host to the gateway IP (e.g. x.x.x.x), port 502, unit ID 1.
- Verify: the inverter should read live values (SOC, PV, temperature), and charge/discharge now holds indefinitely.
Pinout: COM port to gateway
The inverter's data-logger port is USB-A shaped but carries RS485, not USB data. Map its pins to the gateway as shown.
- The two outer pins are +5 V and GND — a multimeter reads about 5 V across them.
- The two inner pins are the RS485 A and B signals.
- Wire GND to the gateway's GND and the inner pins to A and B. Leave +5 V unconnected and power the gateway from its own 12 V supply.
- If it doesn't reply after setup, swap A and B — which inner pin is which is a coin-flip.
Removing the WiFi stick means SolisCloud (the Solis phone app) no longer receives data — with the gateway, everything stays on your own LAN. Only one Modbus master can talk to the inverter at a time, so don't run another controller against it in parallel.
Work on the low-voltage COM wiring only, and if you're unsure about the inverter's ports, check with your installer. This is DIY, at your own risk.
Adding your devices
Add the inverter by the IP address of the RS485 gateway (see the RS485 gateway section above), then optionally add the Battery and Grid devices.
- Give the RS485 gateway a fixed (DHCP-reserved) IP on the same LAN as your Homey Pro.
- Add the Solis Inverter device and enter that IP; pairing reads the serial to confirm the link.
- Add the Solis Battery and Solis Grid devices and pick the inverter as their parent.
- Reading starts immediately. Control does nothing until you build a Flow for it (or enable the price optimiser in the device settings), so the app stays hands-off until you wire it up — and make sure no other controller is on the inverter's Modbus.
Important — feed the optimizer your meters. The inverter's own meter can't see your house loads, so if you use the price optimizer (or the self-consumption trim), link two whole-home readings from any Homey energy meter via Flows: Report grid power (+ import / − export) and Report house load (real consumption, excluding the EV charger). Build one Flow per meter — “When [meter] power changed → Solis: Report … [power]”. Without them the optimizer falls back to a rougher derived estimate. If you happen to own a Plugwise Smile P1 or Shelly Pro 3EM, the optional Grid/House-load meter settings can poll them directly instead.
Pick Solis Inverter first. Battery and Grid are added the same way afterwards and ask you to pick this inverter as their parent.
Enter the gateway's IP. Pairing reads the inverter serial to confirm the link before the device is created.
Only one Modbus master can talk to the inverter at a time. If reads fail, another app or controller is likely holding the connection — stop it first.
Settings, group by group
Almost everything is configured per device, on the Solis Inverter — open it from the device tile and tap the gear (Advanced settings). The app's own page (Apps → Solis Hybrid → Configure) is just an information note; there is nothing to set there. The Battery and Grid devices have no settings of their own.
All settings live under the Solis Inverter device, grouped like this. Only Connection is required — the rest are optional.
Connection
The one group you must fill in. Enter the RS485 gateway's IP under Data logger IP; the Modbus TCP port (502) and unit ID (1) suit almost every gateway. Polling interval (default 10 s) is how often Homey reads the inverter — lower is snappier, higher is gentler.
Load following
Bounds the “Cover the house from the battery” action: the maximum discharge power it may use, the grid level it aims to hold (0 W = neither importing nor exporting; negative keeps a deliberate export margin) and the deadband — how far the grid may drift before it corrects. Widen the deadband if you see it hunting.
Inverter
Serial number is read-only, filled in during pairing so you can confirm you're talking to the right unit. Rated power is the kW in your model name (S6-EH3P15K-H = 15 kW): forced charging, discharging and export limits are capped just below it. Leave it at 10 for a 10 kW model.
Battery protection
Minimum battery level (default 10 %) is the app's own floor: it never discharges below this, whatever a Flow or the price optimizer asks, and it stops as soon as the level is reached. That one lives in the app only. The other two are the inverter's own settings, written straight to it and kept in sync if you change them in SolisCloud or on the unit: Reserved SOC (default 20 %) is the backup reserve it holds back in self-use rather than spending on the house, and Self-use minimum SOC (default 15 %) is its built-in over-discharge protection — the last line of defence beneath everything else.
Grid protection
Set your Grid connection (1- or 3-phase) and Main fuse per phase (default 25 A). The app caps battery grid-charging so the battery and a simultaneously-charging EV can grid-charge together without exceeding your connection or tripping the main breaker. It sizes charging against your true household load (battery + EV + house) and treats solar as a bonus — never as headroom — so a cloud that suddenly cuts your PV can't push the total over the fuse; the battery yields within seconds. Needs a live whole-home grid reading (see Report grid power, or the Grid meter group below); set the fuse to 0 to disable. With a Plugwise Smile P1 polled directly (Grid meter group), it also watches each phase separately, so a single-phase appliance such as a washing machine heating up can't push one phase over the fuse while the total still looks fine.
Maximise self-consumption
Optional. When enabled, it trims battery charging so spare solar covers the house instead of importing from the grid. It needs a whole-home meter reading fed in via the Report grid power Flow. Max charge current, Deadband and Grid target fine-tune how hard and how smoothly it trims.
Follow-the-sun EV charging
Optional and inverter-safe — it writes nothing to the inverter. When enabled it emits Flow triggers recommending an EV charging current to soak up surplus solar; you wire those to your charger in a Flow. Phases, min/max current, Grid target, Deadband and Adjust interval shape the recommendation.
Inverter wake-up
On by default. When the battery is full and the inverter stalls at near-zero output in full sun, it sends a brief export pulse to wake it so the surplus is exported instead of leaving the house on the grid. Wake pulse power, Standby threshold, Confirm polls and Cooldown tune when and how it nudges.
Price optimizer (advanced)
Optional day-ahead price optimization. It hands battery charge/discharge to a separate self-hosted optimizer service (not part of the app). Enable it, then give the service's URL, API key and a poll interval. Leave it off unless you run that service — the app is fully standalone without it.
Grid meter (P1) (optional)
An alternative to the Report grid power Flow: read whole-home grid power straight from a Plugwise Smile P1 on your LAN. Enter its IP and Smile ID. This feeds the same grid signal the self-consumption trim and grid guard use.
House-load meter
Diagnostics (advanced)
Debug only. Logs the inverter's real-time dispatch registers each poll for troubleshooting. Leave it off in normal use.
Credits
Solis is a trademark of Ginlong Technologies. Unofficial community app — not affiliated with or endorsed by the manufacturer.